SS2C smart cylinder positioner

SS5C_fail-freeze
SS2C_cylinder
SS2C_valve
SS5C_fail-freeze
    

Description

Smart performance with innovative and ever-strong coil module even under harsh working environments

Main features

  • Auto-calibration for optimum conditions
  • Precise control performance and high dynamic response
  • Easy operation with fork-key pads and full text graphical LCD
  • Single and double acting
  • Low air consumption due to piezo electric microvalve
  • Pressure regulator built-in to eliminate variations in supply air pressure
  • Problem-free characteristics on a small actuator
  • High resistance against shock and vibration
  • Mounting on rotary actuators according to VDI/VDE3845

Options

  • Output position transmitter (4 - 20 mA)
  • 2 x alarm limit or micro switch (SPDT)
  • By-pass (Auto/Manual switch)
  • Explosion proof type (Ex ia IIC T6)
  • HART communication
  • Profibus PA communication
  • Foundation FF communication

Specifications

Communication Wthout HART Profibus PA F. Fieldbus
Input signal/bus voltage  4-20mA @ 24 VDC    9 - 32 VDC
Min. / Max. Current 3.6 mA / 50mA -
Current Consumption     15 mA 16 mA
Voltage Drop (Res.) 8.7 VDC (435Ω @ 20mA) 9.4 VDC (470Ω @ 20mA)  -  -
Stroke / Angle Linear type : 8 - 130mm | Rotary type : 25 - 120°
Air Supply Pressure 1.4 - 7.0 bar (20 - 100 psi)
Output Pressure Range 0 - 100% of supply air pressure
Air Capacity 80 ℓ/min = 4.8 Nm3/h = 2.8 scfm (Sup = 1.4 bar) | 233 ℓ/min = 14 Nm3/h = 8.2 scfm
Air Consumption 2.8 ℓ/min = 0.17 Nm3/h = 0.1 scfm (Sup = 1.4 ~ 6 bar) 
Linearity < ±0.3% F.S
Sensitivity    < 0.2% F.S
Hysteresis < 0.2% F.S
Repeatability < 0.2% F.S
LCD Indicator 4-digit LCD indicator
Adjustable Speed 1 - 1000 (lowest 1, highest 1000)
Scan Time 2ms
Shut-off Value Range 0 ~10% of position signal
Valve Action Direct action(DA) / reverse action(RA)
Operating Temperature -40 ~ +80℃
Pneumatic Connections PT 1/4, NPT 1/4
Electrical Connections PT 1/2, NPT 1/2, M20 x 1.5
Protection Class IP66 | Intrinsically safe (Ex ia IIC T6/T5) | T6 : -40 ~ +40℃ | T5 : -40 ~ +80℃
Body Material Aluminum die-cast / powder-painted
Weight According to cylinder size and configuration

How to order ...

SS -  A   B   C   D   F   G   H   I   J   K   L
 
 
 
A - Positioner type
 
 
[2] - SS2 smart cylinder positioner
[3] - SS3 smart explosion proof cylinder positioner
[5] - SS5 smart fail freeze cylinder positioner
 
 
 
B - Feedback sensor / lever
 
 
 
[C] - Linear sensor
[M] - Mechanical cam
 
 
   
C - Protection class
 
     
SS2/SS5
[I] - Intrinsic safe ATEX/IECEx - Ex ia IIC T6/T5 (Only M type)
[K] - Intrinsic safe KTL - Ex ia IIC T6/T5 (Only M type)
[W] - Standard IP66
SS3
[F] - Explosion-proof ATEX/IECEx - Ex d IIC T6/T5 (Only M type)
[K] - Explosion-proof KTL - Ex d IIC T6/T5 (Only M type)
         
D - Cylinder stroke
         
[0050] - 50 mm
...
[1000] - 1000 mm
Other on request
           
F - Cylinder type 
           
[P] - ISO 15552 aluminium profil type
[T] - ISO 15552 Tie rods type
[S] - Tie rods compact type
             
G - Bore size
             
[050] - DN50
...
[320] - DN320
               
H - Gauge block
               
[N] - Sans
[1] - 6 bar
[2] - 10 bar
                 
I - Bypass
                 
[N] : None
[Y] : Included (Auto/Manual screw for SS2/SS3 only)
                   
J - Position feedback
                   
[N] - None
[O] - 4-20 mA
[S] - 2 x microswitch (SPDT)
[M] - 2 alarms + 4-20 mA
[Q] - 2 x microswitch (SPDT) + 4-20 mA
                     
K - Communication
                     
[N] - None
[H] - HART
[P] - Profibus PA
[F] - Fieldbus FF
                       
L - Fail position
                       
[N] - None
[O] - Open
[C] - Close
[F1] - Freeze on failure (fixe pres. @ 2.4 bar)
[F2] - Freeze on failure (pres. adjustable)
 
SS - A B C D F G H I J K  L

Code example

 Code example description : SS2C-W 0 4 0 0 S 2 0 0 2 Y N H F 2
Product : [SS2C] - SS2 smart cylinder positioner
Feedback sensor / lever : [C] - Linear sensor
Protection class : [W] - Standard IP66
Cylinder stroke : [0400] - 400 mm
Gauge block : [2] - 10 bar 
Cylinder type : [S]Tie rods compact type
Bore size : [200] - DN200
Gauge block : [2] - 10 bar
By-pass : [Y] - Included (Automatic/Manual screw) 
Position feedback : [N] : None
Communication : [H] : HART
Fail position : [F2] - Freeze on failure (pres. adjustable)